NEW QUESTION 25
Which card connects to the PCI bus, is physically smaller than a on the system board of a Dell EMC PowerEdge 14G server?

  • A. NDC
  • B. OCP
  • C. FPGA
  • D. PCIe

Answer: D

 

NEW QUESTION 26
You must configure a BOSS card with 2 x 120GB drives for a Dell EMC PowerEdge server. What is the only supported mode?

  • A. RAID 5
  • B. Non-RAID Mirroring
  • C. RAID 0
  • D. RAID 1

Answer: C

 

NEW QUESTION 27
What is used by the Lifecycle Controller to directly back up the server profile on a 14G Dell EMC PowerEdge server?

  • A. USB Flash drive
  • B. vFlash SD card
  • C. IDSDM SD card
  • D. Network share

Answer: D

 

NEW QUESTION 28
An engineer needs to install an additional PSU on an existing, single PSU Dell EMC PowerEdge R740. They complete the initial installation and cabling procedures. They connect an AC cable and the power distribution unit produces normal AC output. The engineer checks power management and sees that the new PSU is in the Failed state.
What task should be completed to troubleshoot this issue?

  • A. Set the PSU AC redundancy to 1+0
  • B. Confirm the System Input Power CAP is not set to Low
  • C. Set the PSU AC redundancy to 1+1
  • D. Verify the new PSU is the same type and wattage rating

Answer: D

 

NEW QUESTION 29
A company that has very specific firmware requirements has acquired Dell EMC PowerEdge servers Any replaced parts of the type must match the original parts identically. The procedure must be as simple as possible with minimal risk.
What action should a technician take to help accomplish this goal?

  • A. Enable the Match Firmware of Replaced Part setting in the system BIOS
  • B. Install and configure a repository manager
  • C. Configure servers to access the remote firmware repository
  • D. Enable the Collect System Inventory On Restart (CSIOR) attribute

Answer: C

 

NEW QUESTION 30
A technician needs to update the IDRAC license on a Dell EMC PowerEdge R740 server from Express to Enterprise. The server has the following components:
* 2x CPUs
* 384 GB RAM
* 6x 1 TB drives
* 1x PSU
The server is connected to active AC, but it is powered down, and it needs to stay powered down No errors are presently displayed How can the technician upgrade the license?

  • A. Power on the server, then connect to the iDRAC and upgrade iDRAC license before powering down the server
  • B. Connect to the iDRAC GUI and upgrade the .DRAC license while the server .s powered down
  • C. The license cannot be upgraded on a single PSU system
  • D. The license cannot be upgraded because the user will not allow the server to be powered on

Answer: C

 

NEW QUESTION 31
What happened on April 30, 2019?


Note: It is necessary to dose (x) the simulator window before you can select a response to this question.

  • A. Option C
  • B. Option D
  • C. Option B
  • D. Option A

Answer: A

 

NEW QUESTION 32
What is the purpose of the Silicon-Based Hardware Root of Trust feature in Dell EMC PowerEdge 14G servers?

  • A. Ensures that no unauthorized BIOS or firmware codes are run
  • B. Ensures that the installed operating system is authentic
  • C. Ensures that the server has a valid Service Tag number
  • D. Ensures that the server boots only when connected to a verified network

Answer: A

 

NEW QUESTION 33
A Dell EMC PowerEdge R740 server requires a vFlash SD card urgently. Additional vFlash Cards and components from other servers are available.
What is the recommended solution?

  • A. Reuse an existing vFlash SD card from either a 13G or 14G server
  • B. Use a configuration option to convert an NVMe drive to a virtual vFlash
  • C. Reuse an existing vFlash SD card from a 14G server
  • D. Use a configuration option to convert BOSS to a virtual vFlash

Answer: C

 

NEW QUESTION 34
How can a technician know whether IDRAC9 System Lockdown mode is enabled?

  • A. Lockdown activation message in yellow box in the iDRAC web GUI Access to LCC is disabled when the server boots
  • B. Lockdown activation message in red box in the iDRAC web GUI Access to LCC requires a password when the server boots
  • C. Lockdown activation message in red box in the iDRAC web GUI Access to LCC is disabled when the server boots
  • D. Lockdown activation message in yellow box in the iDRAC web GUI Access to LCC requires a password when the server boots

Answer: C

 

NEW QUESTION 35
What is the correct order of steps taken during the BIOS/UEFI Recovery process?

Answer:

Explanation:

 

NEW QUESTION 36
A Dell EMC PowerEdge 14G server uses Intel OPTANE DC Persistent Memory in App Direct mode. What is the minimum size DIMM supported for this type of memory?

  • A. 512 GB
  • B. 64 GB
  • C. 128 GB
  • D. 256 GB

Answer: D

 

NEW QUESTION 37
Match each status LED indicator on the Dell EMC 14G PowerEdge server with its corresponding condition.

Answer:

Explanation:

 

NEW QUESTION 38
Starting from which Dell EMC PowerEdge server hardware generation is the Micro SD card in the IDSDM/vFlash module supported?

  • A. 12G
  • B. 14G
  • C. 11G
  • D. 13G

Answer: B

 

NEW QUESTION 39
What is required for iDRAC Direct 2.0 to connect with IDRAC9 interfaces such as RACADM and WSMAN?

  • A. Wi-Fi connection
  • B. NFC connection
  • C. Micro-AB USB
  • D. Ethernet cable

Answer: C

 

NEW QUESTION 40
A technician needs to repurpose a Dell EMC PowerEdge server. The server has dual processors with 18 cores each The OS only "sees" 24 threads in total.
Which setting should the technician change in Processor Settings in the System BIOS?

  • A. Virtualization Technology
  • B. System Profile
  • C. Number of Cores per Processor
  • D. HyperThreading

Answer: B

 

NEW QUESTION 41
You are Investigating a disk error on a Dell EMC PowerEdge server and discover a Hot Spare has not been assigned to the Virtual Disk Group. Use the simulator to assign the Global Hot Spare. When you have finished using the simulator, dick Next.

Answer:

Explanation:
Send us your suggestion for this simulation task.

 

NEW QUESTION 42
......

Free DES-4122 Exam Dumps to Improve Exam Score: https://www.easy4engine.com/DES-4122-test-engine.html